Welcome to the Veson Nautical Knowledge Base. In the Help Center, you can view the same articles and contact support as needed.
IMOS On-Prem - Bunker Curve Parameters
Error rendering macro 'excerpt-include' : No link could be created for 'help:IMOS Documentation'.
You can include Bunker Curve Parameters in the calculation of fuel consumption for LNG vessels.
- Do any of the following:
- On the Vessel Consumption tab, click .
- On the Time Charter In Performance tab, click .
- On the Time Charter Out Performance tab, click .
- On the Bunker Curve Parameters form, complete the following fields:
- Speed From: Defaults to the lowest speed in the Speed Consumption Table
- Speed To: Defaults to the highest speed in the Speed Consumption Table
- Step Size: Defaults to the difference between Speed To and Speed From
- To modify a Fuel Type or Group:
- Select the Calc check box.
- If you want to modify LNG, make sure the Generate LNG rates from FOE check box is cleared.
- Ballast and Laden Coefficients C and B are specified based on charter party vessel conditions; specify new values.
- To recalculate the Speed Consumption Table, click OK.
- When the table recalculates, rows that do not match speeds calculated based on Speed From, Speed To, and Step are deleted.
- For each modified Fuel Type or Group, consumption rate = C*EXP(B*speed).
- When the Generate LNG rates from FOE check box is selected, LNG consumption rate = C*EXP(B*speed)/FOE Conversion.
Still need help? Visit the Veson Nautical Help Center.
Copyright © 2017-2024 Veson Nautical LLC All Rights Reserved - Privacy Notice | End User Terms of Use