Insert excerpt |
---|
| IMOS Documentation | IMOS DocumentationGetting Started with IMOS On-Prem |
---|
| Getting Started with IMOS On-Prem |
---|
nopanel | true |
---|
|
To set up You can configure bunker consumption used for cargo heating in the following locations:
...
Table of Content Zone |
---|
|
Data CenterCargo heating consumption for a voyage references the consumption rates from the Vessel Consumption tab and adheres to the ECA Fuel Zone configuration. - The default value is the first general-type fuel with a heating rate defined.
- If no such fuel exists, the first low sulfur fuel with a heating rate is used.
- If there is still no match, a high sulfur fuel is chosen. If there is no match at all, fuel type and rate are cleared from the cargo and heating is disabled.
Vessel Consumption TabWhen creating a tanker Vessel, on the Consumption tab, you can specify heating consumption for one or more fuel types (in MT/day). Image Added Fuel ZonesOn the Fuel Zones form, for each ECA zone, you can define which fuel types can be used for heating. Image Added Voyage Estimate, Column View |
...
On a Voyage Estimate, Column View, if the vessel is a tanker, an H check box appears next to the Cargo field. - If there is one cargo in the calculation, it can be selected to turn on heating and use the default values from the Data Center.
- If multiple cargoes are used, it is disabled and is selected when one or more cargoes have heating set.
|
The default value is the first general-type fuel with a heating rate defined. If no such fuel exists, the first low sulfur fuel with a heating rate is used. If there is still no match, a high sulfur fuel is chosen. If there is no match at all, fuel type and rate are cleared from the cargo and heating is disabled.
...
CP Terms DetailsTo enable cargo heating on the CP Terms Details |
...
Cargo Bunkers tab, set Heating Cons to any value other than Disabled. Image Added - Heating consumption data are pulled from the Data Center,
|
...
- but consumption rates can be overridden. User-entered fields appear highlighted in blue and are used in place of the system-calculated values.
- Heat Days can be used to specify how many days the selected fuel type will be used to heat the cargo.
The resulting quantity of fuel consumed for heating appears in the P&L using the specified bunker price. |
...
Expand |
---|
title | Related Configuration Flags |
---|
|
Name/Flag | Description |
---|
Cargo Bunker Ramp Factor Load CFGCargoBunkerRampFactorLoad | The value set in this flag is used as the factor applied to the Heating/Cooling consumption at the Cargo's first Load |
|
|
...
port. | Cargo Bunker Ramp Factor Disch CFGCargoBunkerRampFactorDisch | The value set in this flag is used as the factor applied to the Heating/Cooling consumption at the Cargo's last Discharge port. |
|
|
Page Properties |
---|
|
Author | Former User (Deleted) | Latest Contributor | Ella Huang | Latest Reviewer | Gabriel Low |
|