Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Insert excerpt
Getting Started with IMOS Documentation
Getting Started with IMOS Documentation
nopaneltrue

To set up You can configure bunker consumption used for cargo heating in the following locations:

...

Table of Content Zone
locationtop

Data Center

Cargo heating consumption for a voyage references the consumption rates from the Vessel Consumption tab and adheres to the ECA Fuel Zone configuration.

  • The default value is the first general-type fuel with a heating rate defined.
  • If no such fuel exists, the first low sulfur fuel with a heating rate is used.
  • If there is still no match, a high sulfur fuel is chosen. If there is no match at all, fuel type and rate are cleared from the cargo and heating is disabled.

Vessel Consumption Tab

When creating a tanker Vessel, on the Consumption tab, you can specify heating consumption for one or more fuel types (in MT/day).

Image Added

Fuel Zones

On the Fuel Zones form, for each ECA zone, you can define which fuel types can be used for heating.

Image Added

Voyage Estimate, Column View

On a Voyage Estimate, Column View

...

, if the vessel is a tanker, an check box appears next to the Cargo field.

  • If there is one cargo in the calculation, it can be selected to turn on heating and use the default values from the Data Center.
  • If multiple cargoes are used, it is disabled and is selected when one or more cargoes have heating set.

The default value is the first general-type fuel with a heating rate defined. If no such fuel exists, the first low sulfur fuel with a heating rate is used. If there is still no match, a high sulfur fuel is chosen. If there is no match at all, fuel type and rate are cleared from the cargo and heating is disabled.

...

CP Terms Details

To enable cargo heating on the CP Terms Details

...

Cargo Bunkers tab, set Heating Cons to any value other than Disabled.

Image Added

  • Heating consumption data are pulled from the Data Center,

...

  •  but consumption rates can be overridden. User-entered fields appear highlighted in blue and are used in place of the system-calculated values.
  • Heat Days can be used to specify how many days the selected fuel type will be used to heat the cargo.

The resulting quantity of fuel consumed for heating appears in the P&L using the specified bunker price.

...


Expand
titleRelated Configuration Flags


Name/FlagDescription

Cargo Bunker Ramp Factor Load
CFGCargoBunkerRampFactorLoad

The value set in this flag is used as the factor applied to the Heating/Cooling consumption at the Cargo's first Load

...

port.
Cargo Bunker Ramp Factor Disch
CFGCargoBunkerRampFactorDisch
The value set in this flag is used as the factor applied to the Heating/Cooling consumption at the Cargo's last Discharge port.

...

Frequently Asked Questions

...




Page Properties
hiddentrue


AuthorFormer User (Deleted)
Latest ContributorElla Huang
Latest ReviewerGabriel Low