Welcome to the Veson Nautical Knowledge Base. In the Help Center, you can view the same articles and contact support as needed.

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 51 Next »

Error rendering macro 'excerpt-include' : No link could be created for 'Veslink IMOS Platform Documentation'.

Veson Nautical has enhanced the existing Fuel Zone configuration and fuel consumption functionality to help our clients comply with the IMO 2020 bunker regulations. The new IMO 2020 functionality accommodates the use of scrubbers on vessels and accounts for the allowance of scrubbers in given ports and zones. By designating the Fuel Types for 3.5%, 0.5%, and 0.1% sulfur and the global areas in which they should be consumed, clients are able to accurately project bunker consumption on estimates and voyages.

On this page:

On Veson.com:

Veson Nautical IMO 2020 Functionality

NoteConfiguration flag CFGEnableScrubberType must be enabled.

Fuel Type Setup

All required Fuel/Lube Types can be set up in the Data Center. Names and descriptions are fully editable, and each entered Type can be designated as High Sulfur, Low Sulfur, or General. Backup Fuel for each Type can also be set, which allows users to specify which Type should be used in the event that the primary Type runs out or is not available.

To disable Backup Fuel types, select the Disable Backup Fuels check box on the Bunker Planning and Voyage Bunkers forms.

Vessel Consumption Categories

On a per-vessel basis (or via default), Fuel Types can be added and further configured with respect to High/Low Sulfur, overriding previous defaults if desired. Veson Nautical recommends reusing the existing fuel grades on the vessel if more than 6 have been used.

Tracking ROBs by Tank

At the vessel level, Bunker Tanks can be specified, including capacity and unit. When using Veslink Voyage Reporting to collect Noon/Arrival/Departure reports from the vessel, these values populate a Bunker Tanks table, allowing entry of ROBs by tank and Fuel Type.

In order to track ROBs/Tank via Veslink forms, the Bunker Tanks must be set up on the vessel level. Once this is set up and the vessel is Active for Veslink, a new form needs to be created with the Bunker Tanks table, which will pull the vessel tank information.

Fuel Zone Configuration

New Fuel Zone sets must be created to comply with IMO 2020; the new Fuel Zone sets must have the IMO 2020 check box selected.

Note: Selecting IMO 2020 for existing Fuel Zone sets will break backward compatibility with respect to P&L.

The Fuel Zones form includes two separate configurations for vessels that are scrubber fitted and those that are not. The Non-Scrubber tab functions the same as the previous Fuel Zones. Both Non-Scrubber and Scrubber tabs allow H (High Sulfur) and G (General) Fuel Types to be selected, instead of only L (Low Sulfur) Types.

An additional zone has been added: Worldwide NON-ECA. This encompasses all waters and ports that are not in ECA zones, and are not marked as Low Sulfur. The Worldwide Zone encompasses ports that are not in ECA Zones but are marked as Low Sulfur.

Scrubbers

The IMO 2020 regulation allows vessels to burn high-sulfur fuel as long as the vessel is fitted with and using a scrubber. Port Authorities around the world will determine their own regulations for permission of scrubber usage at the port. To accommodate the regulations, Veson Nautical is adding the selection of the types of scrubbers on both the Vessel (in use) and Port (allowed) levels.

There are 3 types of scrubbers:

  • Open Loop scrubbers allow for the retained emission waste to be dumped into the water.
  • Closed Loop scrubbers require the vessel to carry the emission and discharge it at designated facilities in port.
  • Hybrid operates as either Open Loop or Closed Loop.

Vessel

On the Vessel form, a Scrubber drop-down menu replaces the previous Use Scrubbers check box.

Four choices are available:

  • None: The vessel is not fitted with scrubbers.
  • Open Loop
  • Closed Loop
  • Hybrid: If Use Scrubbers was previously selected for a vessel, it defaults to a Hybrid Scrubber.

Port

On the Port Properties panel, a Supported Scrubbers drop-down menu appears.

Four choices are available:

  • Info N/A (default): Information is not available.
  • Open Loop: Open Loop scrubbers are allowed in port; if the vessel has Closed Loop scrubbers, it will also be allowed.
  • Closed Loop: Only Closed Loop scrubbers are allowed.
  • Not Allowed: Scrubbers are not allowed at all.

When configuration flag CFGEnablePortFuelAvailability is enabled, a Fuel Type/Grade Availability grid appears on the Port form, in which the Fuel Types and Grades that are available at the port can be captured.

These fuels appear when you hover on ports in the Estimate and Voyage map views.

Consumption Logic

If a vessel has scrubbers active, and G or H Fuel Type is designated for in-port consumption on the Fuel Zone Scrubber tab, the system will use the following logic to determine what kind of consumption to project:

Vessel ScrubberPort AllowanceFuel Consumed
OpenOpenG or H from Fuel Zones
ClosedClosedG or H from Fuel Zones
HybridOpen/ClosedG or H from Fuel Zones
OpenClosedL grade
Any Scrubber TypeNot AllowedL grade from Fuel Zones

Recommended Configurations

The below recommendations outline configurations based on commonly used existing setups. However, the features described above offer significant flexibility and can accommodate a wide range of setups.

Vessels/Fleets with Scrubber-Fitted Vessels

The below recommendations outline configurations based on commonly used existing setups. However, the delivered features described above offer significant flexibility and can accommodate a wide range of setups.

General Assumptions

There are 3 fuel types:

  1. 3.5% (only scrubber-fitted vessels will have this onboard)
  2. 0.5% (the new high-sulfur fuel)
  3. 0.1% (the new low-sulfur fuel)

Assumptions for Scrubber-Enabled Vessels

For scrubbers with 0.5% output:

  • In areas where 0.1% is required, the vessel will either burn LSG 0.1% or ultra-low fuel oil 0.1%
  • In areas where the port restricts Open Loop scrubbers, the vessel will either burn LSG 0.1% or ultra-low fuel oil 0.1%
  • Scrubbers with 0.1% output:
  • In areas where the port restricts Open Loop scrubbers, the vessel will either burn LSG 0.1% or ultra-low fuel oil 0.1%

Vessels or Fleets Burning Compliant Fuel Only (Vessels without Scrubbers)

  1. Fuel Types and Fuel Zones
    1. On the Fuel/Lube Types form, either:
      • Add new Types for compliant fuel and set 0.5% to H and 0.1% to L.
      • Reuse existing fuel types, for example: designate the current H as compliant 0.5%, and the current L as 0.1%.
  2. Select appropriate compliant 0.5 % H backup of 3.5% H, and 0.1% or LSG as a backup for 0.5%.
    1. During the period as your fleet transitions from noncompliant to compliant fuel consumption, compliant fuel can be set at the backup fuel for noncompliant fuel, with the consumption rate set to 0.00.
  3. Vessel Setup
    1. On the Vessel Consumption tab, add the H and L grade fuels, unless the past fuel types will be reused.

Fleets with Scrubber-Fitted Vessels

  1. Define compliant and high-sulfur fuels:
    1. Since the vessel has scrubbers, she will most likely continue to consume and stem 3.5% fuel, configured as an H type. As such, there is no need to define compliant fuels for this vessel.
    2. If you envision the need to stem compliant fuels for a scrubber-fitted vessel, you may define such fuels as per the configuration in the VIP - Compliance with IMO 2020 section above.
    3. Select appropriate H and L Fuel Types for backup:
      1. 3.5% (H) should be backed up by 0.5% (H).
      2. 0.5% (H) should be backed up by 0.1% (L) or gas oil.
      3. If one H fuel is selected to back up another H fuel, then the backup fuel consumption rate on the vessel should be 0.00 unless the first H fuel is designated in the Fuel Zones for At Sea and In Port consumption for all appropriate zones.
    4. On the Fuel Zones form:
      1. Create new IMO 2020 Fuel Zone sets (must include Worldwide and Worldwide NON-ECA) to consume the designated H grade fuel on the Scrubbers tab.

        Note: Selecting IMO 2020 for existing Fuel Zone sets will break backward compatibility with respect to P&L.

      2. For Vessels that will not use scrubbers in the ECA zones, configure the specific ECA Zones with appropriate L grade fuel and the consumption rate, if necessary.
      3. Worldwide NON-ECA is now a 0.5% sulfur emission zone, and the Consumption At Sea for this zone can be set up to consume 3.5% fuel with a scrubber.
      4. We foresee that only the North Sea and 200NM zones will remain as ECA zones, therefore in these zones, the users should select 0.1% fuel to be consumed, however, the user has an option to configure the remaining zones.
  2. Configure vessels:
    1. On the Vessel form, select the Scrubber the ship has installed: Open Loop, Closed Loop, or Hybrid.
    2. On the Vessel Consumption tab, add the H grade fuel 3.5% to be consumed with the scrubber, H grade fuel 0.5% in case the scrubber is not used or not allowed, and L grade fuel 0.1% when in the ECA zone.
      1. This section presents two scenarios that revolve around the maximum limits of 6 fuel types on a vessel:
        1. If you can add more new compliant fuels on the vessel, they should do so in accordance with the recommendation above.
        2. If you cannot add more new fuel types on a vessel because the vessel already has 6 fuels registered and used, the user should re-utilize the existing fuels.
  3. Configure ports:
    1. On the Port form, select which Supported Scrubbers are allowed in a given port. The default of the port scrubber drop-down menu is Info N/A (Information Not Available); in those cases, the system will by default calculate fuel consumption that is set up in the Fuel Zones.

Debunkering Best Practices

If needed, you can debunker a lifted quantity or transfer bunker quantities between two types. On the Bunker Liftings form, enter a negative lifted quantity.

On the Bunker Lifting Selection form, select the FIFO lot to remove the quantity from; it does not have to be the last lot. The FIFO queue is modified.

The price for the negative quantity is defined by the invoice price.

Frequently Asked Questions

Will there be a different solution for adding more than 6 fuel types?

Veson Nautical is actively discussing a more seamless solution. Currently, there is no timeline for this.

Why am I seeing negative bunker consumption on the estimated bunkers even though I have set up backup fuels and they are present on the vessel?

Most of the time, the reason for this is because there is not enough initial quantity of the backup fuel available for the backup. Add more backup fuel to estimated consumption and there will not be negative figures.

Can I seamlessly switch from using scrubbers on the voyage and then just burning compliant fuel?

Yes, on the Bunker Planning form, clear the Use Scrubbers check box.

Will the LS Only functionality change?

No, the LS Only functionality will remain the same.

Will ROBs/Tank information be available in VIP?

At the moment, this information tracking is only available in the offline forms and reporting capacities.

What if I already had the “Use Scrubbers” check box selected on the vessel?

If Use Scrubbers was previously selected for a vessel, it defaults to a Hybrid scrubber.

Timeline

Veson Nautical is collecting feedback and will consolidate it into the next phase of feature development.


 Related Configuration Flags
Name/FlagDescription
Enable Port Fuel Availability
CFGEnablePortFuelAvailability
When enabled, a new Fuel Availability grid is added to the Port form in the Data Center where the Fuel Types and Grades that are available at the port can be captured.
Enable Scrubber Type
CFGEnableScrubberType
When enabled, a scrubber drop-down menu appears on the Port, Voyage Bunkers, Bunker Planning, and Vessel forms accessed through an Estimate. On the Port and Vessel forms, the drop-down menu reflects scrubber values allowed at the port and equipped in the vessel. On the Voyage Estimate and Voyage, it reflects the scrubber type used for bunker calculations. On the Vessel form, the “Use Scrubbers” check box is replaced with the new “Scrubber Type” drop-down menu. The Fuel Zones form has two tabs to support “Scrubber” and “Non-Scrubber” configurations. These new options facilitate bunker calculations to use the new IMO 2020 regulations.
Enable Vessel Scrubbers
CFGEnableVesselScrubbers
Adds a Scrubbers Active field to the Vessel form, in which you can record the date when scrubbers were installed.
  • No labels