Cargo heating consumption for a voyage references the consumption rates from the Vessel Consumption tab and adheres to the ECA Fuel Zone configuration.

  • The default value is the first general-type fuel with a heating rate defined.

  • If no such fuel exists, the first low-sulfur fuel with a heating rate is used.

  • If there is still no match, a high-sulfur fuel is chosen. If there is no match at all, fuel type and rate are cleared from the cargo and heating is disabled.

...

On the Fuel Zones form, for each ECA zone, you can define which fuel types can be used for heating.

...

Estimate Column

On an Estimate column, if the vessel is a tanker, a Heat check box appears next to the Cargo field.

...

Expand
titleRelated Configuration Flags

Name/Flag

Description

Cargo Bunker Ramp Factor Load
CFGCargoBunkerRampFactorLoad

The value set in this flag is used as the factor applied to the Heating/Cooling consumption at the Cargo's first Load port.

Cargo Bunker Ramp Factor Disch
CFGCargoBunkerRampFactorDisch

The value set in this flag is used as the factor applied to the Heating/Cooling consumption at the Cargo's last Discharge port.